BQRBJ - TCM68 CLEAR TONER
- MSDS: BQRBJ
- Manufacturer: CALCOMP
- Product Name: TCM68 CLEAR TONER
- National Stock Number: 6850-00N036505
Product Identification
Product ID:TCM68 CLEAR TONER
MSDS Date:03/01/1991
FSC:6850
NIIN:00N036505
MSDS Number: BQRBJ
Responsible Party
ANAHEIM, CA 92801
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 714-821-2114
Preparer: CRAIG SUNDQUIST
Cage: IO122
Contractor
Telephone: 714-821-2290
Cage: 14668
Ingredients
IS SUFFICIENT TO PVNT EXCEEDING EXPOS LIM. USERS
RTECS: 9999999ZZ
HYGIENIST IF A CONCERN REGARDING EXPOSURE ARISES.
RTECS: 9999999ZZ
AS REPLENISHER, MAY STAIN CLOTHING.
RTECS: 9999999ZZ
ISOPARAFFIN SOLVENT; (ALIPHATIC HYDROCARBON (ISOPAR G))
CAS: 64742-48-9
Fraction By Weight: >100%
STUDIES W/FEMALE RATS & MALE & FEMALE MICE & IN
RTECS: 9999999ZZ
OF HUMAN STUDIES, THERE WAS NO CLINICAL EVIDENCE OF
RTECS: 9999999ZZ
UNLIKELY THAT KIDNEY EFTS OBSERVED IN MALE RATS HAVE
RTECS: 9999999ZZ
RECOM VAP LIM IN WORKPLACE.
RTECS: 9999999ZZ
OF WATER. DO NOT INDUCE VOMIT. CALL PHYS
RTECS: 9999999ZZ
FOR VOLAT, COMBUST VAPS FROM ABSORBED MATL.
RTECS: 9999999ZZ
PETROLEUM BASED OILS. CONT A LICENSED HAZ
RTECS: 9999999ZZ
ASSISTANCE. POSS DISP METH INCL INCIN/RECYCLING FOR
RTECS: 9999999ZZ
BE USED W/CALCOMP PLOTTERS. "EMPTY" CONTRS RETAIN
RTECS: 9999999ZZ
OF HEATING, AIR CNDTNG, & REFERIGERATING ENGINEERS
RTECS: 9999999ZZ
UNDER SOME CNDNTS OF USE/COMBINATIONS OF EQUIP,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN: CAN CAUSE DRY OF
SKIN/IRRIT. EYES: CONT MAY CAUSE IRRIT. INHAL: INHAL OF VAPS MAY
CAUSE HDCH & DIZZ. INGEST: PROD HAS A LOW ORDER OF ACUTE ORAL &
DERMAL TOX, BUT IF ASPIRATED INTO LUNGS D URING INGEST/VOMIT, MAY
CAUSE MILD TO SEVERE PULM INJURY & POSSIBLY DEATH. HIGH VAP CONC
(>1000PPM) (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ARE IRRITATING TO EYES & RESP TRACT,
MAY CAUSE HDCH & DIZZ, ARE ANESTH, & MAY HAVE OTHER CNS EFTS. DEATH
IS POSS IF EXPOS TO VERY HIGH CONC FOR PRLNGD PERIODS. PERSONS
SENSITIVE TO HYDROCARB ON EXPOS MAY EXPER DISCOMFORT WHEN EXPOS TO
CONC BELOW ESTABLISHED SAFE EXPOS LIM. LAB ANIMAL STUDIES HAVE
(SUPP DATA)
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE AN
EXISTING DERMATITIS.
First Aid
First Aid:EYE:FLUSH W/CLEAR WATER FOR @ LST 15 MIN/UNTIL IRRIT
SUBSIDES. IF IRRIT PERSISTS, CONT PHYS. SKIN: REMOVE CONTAMD CLTHG.
WASH SKIN THORO W/SOAP/WATER. DO NOT REUSE CONTAMD CLTHG UNTIL SOLV
HAS BEEN RE MOVED. INHAL: REMOVE TO FRESH AIR. CALLPHYS IMMED. IF
BRTHG IS IRREG/STOPPED, START RESUSCITATION IF TRAINED. ADMINISTER
OXYGEN IF AVAIL. INGEST: DILUTE CONTENTS OF STOM W/SEVERAL GLASSES
(ING 6)
Fire Fighting
Flash Point Method:TCC
Flash Point:100F,38C
Lower Limits:0.8%
Upper Limits:7%
Extinguishing Media:FOAM, DRY CHEMICAL, OR CARBON DIOXIDE. USE WATER
SPRAY (FOG) TO COOL FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:KEEP PROD AWAY FROM SOURCES OF IGNIT SUCH
AS HEAT, SPARKS, PILOT LIGHTS, STATIC ELECTRICITY, ELEC APPLIANCES
& OPEN FLAMES. AVOID EXTING W/WATER- IT (SUPP DATA)
Accidental Release
Spill Release Procedures:ELIM ALL IGNIT SOURCES. RECOVER FREE PROD BY
ADDING SAND, EARTH/OTHER SUITABLE ABSORB TO SPILLED LIQ. KEEP
NON-ESSENTIAL PERS AWAY. AVOID BRTHG VAPS. VENT CONFINED SPACES.
CLEAN-UP ABSORB MATL & DISPO SE OF PROPERLY. CONTINUE TO OBSERVE
PREC (ING 7)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTRS CLSD WHEN NOT IN USE. DO
NOT SMOKE WHEN USING PROD. MINIMIZE BRTHG VAP/MIST. USE W/ADEQ
VENT. AVOID PRLNGD/RPTD CONT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NOT NEEDED WHEN USED AS INTENDED W/CALCOMP PROD.
IN CONC EXCEEDING RECOM SAFE EXPOS LIM, SUCH AS DURING A MAJOR
SPILL, USE A NIOSH/MSHA APPRVD CHEM CARTRIDGE RESP EFTIVE FOR ORG
VAPS.USE NIOSH/MSHA AP PRVD FRESH AIR RESP IN CONFINED SPACES.
Ventilation:NO SPECIAL VENT IS NEEDED WHEN USED AS INTENDED W/CALCOMP
PROD. NORM OFFICE VENT CONFORMING TO AMERICAN SOCIETY(ING 11)
Protective Gloves:NITRILE/NEOPRENE.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SHOULD NOT BE NEEDED WHEN USED AS INTENDED
TO CALCOMP PROD. WEAR A CHEM RESISTANT APRON WHEN CLEANING MACHINES
(ING 15)
Work Hygienic Practices:WHENEVER HNDLG CHEM, ALWAYS USE GOOD PERSONAL
HYGIENE PRACTICE, SUCH AS WASHING YOUR HANDS AFTER DONE.
Supplemental Safety and Health
PH: ESSENTIALLY NEUTRAL. % VOLAT: 100@1ATM & 25C. EXPLO HAZ: TENDS TO
SPREAD HYDROCARBON SOLV FIRES. EFTS OF OVEREXP: SHOWN THAT PRLNGD &
RPTD INHAL EXPOS TO LIGHT HYDROCARBONS VAPS IN SAME NAPHTHA BO
ILING RANGE AS PROD CAN PRDCE ADVERSE KIDNEY EFTS IN MALE RATS.
HOWEVER, THESE EFTS WERE NOT OBSERVED IN SIMILAR (ING 2)
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:>311F,>155C
Vapor Pres:<10@25C
Vapor Density:5
Spec Gravity:0.75(H*2O=1)
pH:SUPDAT
Evaporation Rate & Reference:0.3(N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE; 0.1%
Appearance and Odor:CLEAR LIQUID. FAINT PETROLEUM HYDROCARBON ODOR.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS LIKE LIQ CHLORINE, CONCENTRATED OXYGEN, & SODIUM
HYPOCHLORITE OR CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:SOURCES OF IGNITON.
Hazardous Decomposition Products:SMOKE, CARBON MONOXIDE, ALDEHYDES, &
OTHER DECOMP PROD WHICH MAY OCCUR IN EVENT OF INCOMPLETE
COMBUSTION.
Disposal
Waste Disposal Methods:RCRA HAZ WASTE NO.-D001. WASTE TONERS &
REPLENISHERS ARE HAZ WASTES AS DEFINED BY 40CFR CHAPTER 1. ASSURE
CONFORMITY W/ALL APPLIC FED, ST, & LOC DISP REGS. WASTE TONERS &
REPLENISHERS ARE COMPATIBLE F OR DISP W/MOST NON-HALOGENATED SOLV &
(ING 8)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.